207
MIDI-Implementation
Anhang
● System exclusive messages related to mode setting
❍Turn General MIDI System On
This is a command message that resets the internal settings of the unit to the General MIDI
initial state (General MIDI System - Level 1). After receiving this message, this unit will
automatically be set to the proper condition for correctly playing a General MIDI score.
Status
Data byte Status
F0H 7EH, 7FH, 09H, 01H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
01H Sub ID#2 (General MIDI 1 On)
F7H EOX (End Of Exclusive)
* Not Received when [SETUP]-[MIDI]-[GLOBAL]-[PAGE 3] RX GM ON is set to
“OFF”.(Initial Value is ON)
* There must be an interval of at least 50ms between this message and the next.
❍Turn General MIDI System Off
When a “GM System Off” is received, the TD-8 is switched to normal mode.
Status Data byte Status
F0H 7EH, 7FH, 09H, 02H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
02H Sub ID#2 (General MIDI 1 Off)
F7H EOX (End Of Exclusive)
* Not Received when [SETUP]-[MIDI]-[GLOBAL]-[PAGE 3] RX GM ON is set to
“OFF”.(Initial Value is ON)
* There must be an interval of at least 50ms between this message and the next.
● Universal Non-realtime System Exclusive Messages
❍Identity Request
* Regarding the Identity Request refer to p. 202.
● Global Parameter Control
❍Channel Pressure
Status Data byte Status
F0H 7FH, dev, 09H, 01H, 0nH, ppH, rrH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (Universal Realtime Message)
dev Device ID (dev: 00H - 1FH Initial value is 10H (17))
09H Sub ID#1 (Controller Destination Setting)
01H Sub ID#2 (Channel Pressure)
0nH MIDI channel (00H - 0FH)
ppH parameter
rrH range
F7H EOX (End Of Exclusive)
pp=0 Pitch Control
rr=28H-58H -24 - +24 semitones
pp=1 Filter Cutoff Control
rr=00H-7FH -9600 - +9450 cents
pp=2 Amplitude Control
rr=00H-7FH 0 - 200%
pp=3 LFO Pitch Depth
rr=00H-7FH 0 - 600 cents
pp=4 LFO Filter Depth
rr=00H-7FH 0 - 2400 cents
pp=5 LFO Amplitude Depth
rr=00H-7FH 0 - 100%
* Even if the Device ID is 7FH (Broadcast), Identity Reply message will be transmitted.
* In the rhythm part (ch.10), ignored this message.
● Data transmission
❍Request data 1 RQ1 (11H)
* Regarding the RQ1 refer to p. 202.
❍Data set 1 DT1 (12H)
* Regarding the DT1 refer to p. 203.
Section 2. Transmit data
* When [SETUP]-[MIDI]-[GLOBAL]-[PAGE 3] SOFT THRU is set to “ON”, messages
received in addition to the following messages are also sent.
● Active sensing
Status
FEH
* This will be transmitted constantly at intervals of approximately 250ms.
■ System exclusive messages
● Universal Non-realtime System Exclusive Messages
❍Identity Reply
* Regarding the Identity Reply refer to p. 205.
● Data Transmission
❍Data set 1 DT1 (12H)
* Regarding the DT1 refer to p. 205.