Performing Feed Correction to Alleviate Horizontal Bands and the Like
Procedure
1.
Print a test pattern.
Press .
Press several times.
Press .
Press to start printing.
2.
Read the correction values from the test pattern.
In the printing example shown below, "-0.40" becomes the correction value.
3.
Enter the correction values that you read.
Press .
Press .
Use to make the setting for the cor-
rection value.
Press to enable the setting.
4.
Go back to the original screen.
Press .
Press to go back to the original screen.
MENU
CALIBRATION
CALIBRATION
TEST PRINT
SETTING
- 0.40%0.00%
W 1346mm
SETUP SHEET
ROLL
Gap present
Overlap
Choose the one that has the smallest gap
and the least amount of overlap.
Test pattern
Current correction value
6-7 Correcting Misalignment for Printing or Cutting