Roland VC-300HD Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Videokonverter Roland VC-300HD herunter. VC-200HD/VC-300HD Command Reference Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
VC-200HD/VC-300HD Command Reference
The basic command syntax consists of a line of ASCII code: “stx” followed by “3 letters (uppercase)” and then a “;”
(semicolon).
The three letters indicate the command type. Also, when there are parameters for the command, a colon is inserted
between the three letters and the parameter. If there are multiple parameters, they are separated with a comma (,).
“stx” This is a signal name (code number 02H (hexadecimal) in ASCII code. It is a control code indicating the start of
a command.
“:” This is a code for this device to recognize the separation of the command and its parameters.
“;” This code is for this device to recognize the end of a command.
Example 1) When sending an input format request, the ASCII code line “stxVIF;” is sent.
Example 2) When loading Preset3, the ASCII code line “stxPSE:2;” is sent.
In the following, stx (02H), ACK (06H), and Xon (11H)/Xoff (13H) are control codes.
Note: When an external device is connected to the VC-300HD and sends a command, please confirm that ACK is
returned before sending the next command.
stxVER;
Send to learn the VC-300HD version.
The version information is returned.
stxACS;
Send to learn the status of the unit.
ACK is returned if the unit is not doing anything.
stxSYN;
Send to learn the sync status of the unit.
The sync status is returned when the unit correctly receives the command.
stxVIF;
Send to learn the input format status of the unit.
The input format status is returned when the unit correctly receives the command.
stxVOF;
Send to learn the output format status of the unit.
The output format status is returned when the unit correctly receives the command.
stxDAT: a,[b,[c,d,e]];
a: Menu number
b: Parameter value 1
c: Parameter value 2
d: Parameter value 3
e: Parameter value 4
Sets the unit's menu. Parameter values 1–4 may need to be sent depending on the menu number. See “Menu Implementation” (P. 3–4) for information
regarding menu numbers and parameter values.
ACK is returned when the unit correctly receives the command. When a:990 is sent, a bulk dump is returned.
For items without parameter value descriptions in “Menu Implementation,” the menu content is executed when the menu number is sent. Please send
all parameters for items that have multiple parameter values.
Command Overview
Commands received by VC-300HD
VER Request for version information (06H)
ACS Request for the active sense
SYN Request for the sync status
VIF Request for the video input format
VOF Request for the video output format
DAT Request for the data set
1
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Commands received by VC-300HD

VC-200HD/VC-300HD Command Reference The basic command syntax consists of a line of ASCII code: “stx” followed by “3 letters (uppercase)” and then a “;

Seite 2 - Commands sent by VC-300HD

1PS stxPSE:a; a: 0–3 (0 Preset1, 1 Preset2, 2 Preset3, 3 Factory Load)Loads the preset.ACK is returned when the unit correctly receives the command. s

Seite 3 - Menu Implementation

Menu Implementation Item NumberItem Name Parameter Values Corresponding Set Value 100 Video Source 0–4 0: i.LINK, 1: CMPNT, 2: DVI-D, 3: DVI-A, 4: SD

Seite 4

1PS 270TC Generate 0–3 0: Off, 1: Free Run, 2: Thru, 3: OffsetNote: With VC-200HD, ERR:5; is returned when 2:Thru or 3:Offset is selected.271 TC Offse