17
4 Adjustment
4
1
2
3
4
4-3 HOW TO UPGRADE FIRMWARE
Remove the Front Table.
It is necessary to prepare the followings to
upgrade the FIRMWARE.
1. Firmware Disk
2. PC with MS-DOS
3. Parallel Cable
Connect the PC and the SX-15/12/8 with the Parallel Cable.
Turn on the DIP SW-3 on the Main Board and connect the
AC adapter.
Open the [download.bat] file in the Firmware Disk.
Some PCs can not use the BAT FILE. Please
refer to the ReadMe File in the Firmware Disk.
STANDBY LED starts blinking slowly when the upgrade is
completed without any problem.
In case of problem, STANDBY LED blinks quickly.
Disconnect the AC adapter and turn off the DIP SW-3 and
then, fix the Front Cover.